We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Strength measurements.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Strength measurements - List of Manufacturers, Suppliers, Companies and Products

Strength measurements Product List

1~6 item / All 6 items

Displayed results

Measurement of magnetic field strength using a loop antenna

[Application Example] Easily measure electric field strength right at your fingertips!

We introduce a case where magnetic field strength in the range of 100 kHz to 30 MHz can be measured using a loop antenna, low-noise amplifier, and signal analyzer. By subtracting the gain of the low-noise amplifier MAP301 from the antenna factor of the loop antenna MAN120 and writing this value as a calibration coefficient into the signal analyzer MSA538, magnetic field strength can be displayed directly. This can be realized as an inexpensive tool for easily measuring electric field strength at hand. 【System Configuration】 ■ Signal Analyzer [MSA538] ■ Loop Antenna [MAN120] ■ Low-Noise Amplifier [MAP301] ■ SMA(P)/N(P) Coaxial Cable ■ SMA(P)/N(J) Coaxial Cable ■ Loop Antenna Stand *For more details, please refer to the PDF document or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Measurement of electric field strength using the antenna factor of a loop antenna.

[Application Example] Easily measure electric field strength from 50 kHz to 30 MHz with a handheld spectrum analyzer and loop antenna.

By using the antenna factor of the loop antenna MAN120, it is possible to measure the electric field strength from 50 kHz to 30 MHz with the handheld spectrum analyzer MSA438. 【Product Introduction】 ■ Spectrum Analyzer MSA438 ■ Loop Antenna MAN120 *For more details, please refer to the PDF document or feel free to contact us. It can be realized as an inexpensive tool for easily measuring electric field strength at hand. 【System Configuration】 ■ Spectrum Analyzer MSA438 ■ MSA438 Calibration Set ■ Loop Antenna MAN120 ■ BNC Cable 1.5m MC314 ■ Conversion Connector N(P)/BNC(J) MA307 ■ Conversion Connector N(J)/BNC(J) *For more details, please refer to the PDF document or feel free to contact us.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Measurement of electric field strength at ETC lanes and ITS spots.

[Application Example] "Electric Field Strength Measurement Device" Essential for the Installation and Maintenance of Roadside Equipment

【Product Introduction】 ■ Handheld Spectrum Analyzer MSA558E ■ DSRC Communication Unit ME9115C (Electric Field Strength) ■ ETC/ITS Spot Electric Field Strength Measurement ME9200 * For more details, please refer to the PDF document or feel free to contact us. Our company provides a testing environment for the development, production, and maintenance of DSRC communication equipment. This time, we would like to introduce the "Electric Field Strength Measurement Device," which is essential for the installation and maintenance of roadside units. Roadside units need to radiate microwaves in a specific direction to prevent radio wave interference between adjacent lanes. Typically, microwaves are radiated towards the area where the onboard unit passes, specifically near the antenna and towards the center of the lane. By measuring the electric field strength in the area where communication occurs, it is easy to confirm whether microwaves are arriving at the intended location. * For more details, please refer to the PDF document or feel free to contact us.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Simple electric field strength measurement using the reference level offset function.

[Application Example] By converting the antenna factor using the reference level offset function of the spectrum analyzer MSA series, the electric field strength can be read directly.

When connecting an antenna to a spectrum analyzer / signal analyzer to measure electric field strength, the electric field strength in decibels (dB) can be converted by simply adding the antenna factor to the measured voltage. This introduces a method for measuring electric field strength using the reference level offset function in the MSA500 or 400 series (measured with an input impedance of 50Ω). 【Product Introduction】 ■ Handheld Signal Analyzer MSA500 Series ■ Handheld Spectrum Analyzer MSA400 Series *For more details, please refer to the PDF document or feel free to contact us. 【System Configuration】 ■ Handheld Signal Analyzer MSA500 Series ■ Handheld Spectrum Analyzer MSA400 Series *For more details, please refer to the PDF document or feel free to contact us.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ASTM F88 Seal Strength Measurement

Seal strength testing as specified in ASTM F88 can be performed.

- This test is a method established by ASTM to evaluate the seal strength of soft barrier materials. - ISO 11607-1 states that as part of packaging system performance testing, "the integrity of the sterilization barrier system must be demonstrated after sterilization and subsequent performance testing." Annex B of this standard describes ASTM F88 as the standard test method for evaluating the seal integrity of medical packaging. - There are three methods for measuring seal strength: 1) Technique A: No support 2) Technique B: Supported at 90 degrees by hand 3) Technique C: Supported at 180 degrees ▼ For more details, please download the PDF document (recommended). ▼ If you need immediate assistance, please contact us using the 'Contact Us' section below.

  • オートグラフ・PXL_20240528_003503682.PORTRAIT.jpg
  • DSCF9802.jpg
  • Contract Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration